Please enable JavaScript to view this site.

TerraScan User Guide

Navigation: Tool Reference > Key-in commands/Spaccels

Key-in commands - M

Scroll Prev Top Next More

Mouse Point Adjustment

Mouse Point Adjustment key-in command activates the Mouse Point Adjustment tool. As long as the tool is active, all data clicks are adjusted to the elevation and/or horizontal location of points loaded into TerraScan.

Syntax:

mouse point adjustment AdjZ=1/AdjXy=0/Point=Closest/Class=2/Within=0.5

Possible parameters:

PARAMETER

EFFECT

AdjZ=n

If given, the elevation of data clicks (vertices of elements) is adjusted. n defines a constant value that is added to the point cloud elevation when vertices are placed. If n=0, the parameter is deactivated.

AdjXy=n

If n=1, the parameter is activated and the xy location of data clicks (vertices) is adjusted. If n=0, the parameter is deactivated.

Point

Points or surface model from which element vertex coordinates are derived: Closest, Highest, Average, Percentile, Lowest, TIN model.

class=n

Point class to adjust to. n defines the class number.

Within=n

n defines the radius of the search area around the mouse pointer location.

Corresponding tool: Mouse Point Adjustment

Move Backward

Move Backward key-in command activates the Move Section tool and moves a section view backward. The key-in command must include a view number (1-8). The section is moved backward by the full depth or half of the depth of the section view, depending on the active setting in the Move Section tool dialog.

Syntax:

move backward [stayactive] ViewNumber

Parameters:

PARAMETER

EFFECT

stayactive

If given, the Move Section tool stays active until a reset click is placed. The section extend is displayed in a top view. A reset click deactivates the Move Section tool and re-activates the tool used before starting the key-in command.

If not given, the Move Section tool does not stay active and the section extend is not displayed. The tool used before starting the key-in command stays active.

ViewNumber

View in which the action is applied. View numbers can range from 1-8.

Corresponding tool: Move Section

Move Forward

Move Forward key-in command activates the Move Section tool and moves a section view forward. The key-in command must include a view number (1-8). The section is moved forward by the full depth or half of the depth of the section view, depending on the active setting in the Move Section tool dialog.

Syntax:

move forward [stayactive] ViewNumber

Parameters:

PARAMETER

EFFECT

stayactive

If given, the Move Section tool stays active until a reset click is placed. The section extend is displayed in a top view. A reset click deactivates the Move Section tool and activates the tool used before starting the key-in command.

If not given, the Move Section tool does not stay active and the section extend is not displayed. The tool used before starting the key-in command stays active.

ViewNumber

View in which the action is applied. View numbers can range from 1-8.

Corresponding tool: Move Section