Not Lite

By scanner routine classifies points according to the scanner number. The number of the scanner that recorded a point can be stored as attribute for laser points in TerraScan FastBinary and LAS files. This is primarily used for laser data from multiple-scanner systems.

byScanner

SETTING

EFFECT

From class

Source class(es).

_select_classes

Opens the Select classes dialog which contains the list of active classes in TerraScan. You can select multiple source classes from the list that are then used in the From class field.

Scanner

Number(s) of the scanner(s) from which to classify points. Separate several scanner numbers by a comma or minus, for example 1-3,5. Use 0-255 for all scanners.

To class

Target class.

Inside fence only

If on, points inside a fence or selected polygon(s) are classified.